Draft systems & serving
Draft Line Balancing Calculator
Find a starting length for your beer line.
Estimate beer line length from your serving pressure, tubing resistance and tap height. Then fine-tune with a cold test pour.
See the method & assumptionsYour setup
Your result
Starting line length
Enter your setup
— m
An estimate to test on your equipment.
Where the pressure goes
- Available for beer line
- —
- Used by elevation
- —
- Other known losses
- —
Make the next pour count.
Leave some extra hose for adjustment. Chill the whole beer path, test with the faucet fully open, and shorten in small steps if the pour is too slow.
Keep serving pressure appropriate for carbonation. A warm faucet, dirty line or overcarbonated keg can still cause foam.
Behind the calculation
A simple balance.
Visible assumptions.
Every input has a job. Here is how it becomes a line length.
The equation
L = (P − G × H − A) / R
- L
- Calculated line length
- P
- Serving gauge pressure
- G × H
- Elevation allowance: 0.5 psi/ft × signed height (≈ 0.1131 bar/m)
- A
- Other known pressure losses
- R
- Line resistance per unit length
Why the tubing value matters
The two vinyl presets use nominal values of 3.00 and 0.85 psi/ft for 3/16″ and 1/4″ internal diameters. Actual resistance varies by product and flow. Use the manufacturer’s value at your intended flow; do not apply vinyl values to barrier tubing.
Height, flow and model limits
The 0.5 psi/ft elevation factor is a draught-industry convention; the manual also gives about 0.43 psi/ft for hydrostatic head. Measure from the keg centre. A lower tap increases the pressure available to the line.
Resistance values imply a flow condition. This model does not independently calculate flow or add an arbitrary “pressure at the faucet.” It assumes one tubing type and excludes pumps, mixed-gas design, nitro restrictors and multi-section long-draw design.
What if the calculated hose cannot reach?
A hose must reach the faucet without stretching or kinking. If the estimate is shorter than the physical route, review the tubing and system design. The calculator checks vertical reach; bends and horizontal distance need your own check.
When this tool asks you to review a result
Review prompts appear above 2 bar (≈ 29 psi) serving pressure, above 2 m (≈ 6.56 ft) of absolute height difference, or for a calculated line shorter than 0.30 m (≈ 0.98 ft) or longer than 6 m (≈ 19.69 ft). A separate prompt appears when less than 5% of the driving pressure remains for the line.
These are editorial prompts chosen for this home-draft tool. They are not manufacturer limits, safety ratings or a validated operating range. Values beyond them are still calculated when mathematically possible; equipment suitability requires its own specifications. Exactly at a threshold, that particular prompt is not shown.
If elevation and other losses exhaust the pressure, there is no positive line-length result. Values indistinguishable from zero at numerical precision receive the same treatment. Tiny positive results are displayed as “< 0.01” instead of a misleading zero.
Sources & review
Brewers Association · Draught Beer Quality Manual, 4th edition
Printed pp. 38–39: elevation convention and nominal tubing values.
Micro Matic · What is restriction?
Set pressure for carbonation, then balance the beer path.
Method reviewed 16 November 2026 · Version 1.1
Reference values are estimates, not a calibration of your tubing.