Franklinbrew

Draft systems & serving

Carbonation Pressure Calculator

Match pressure to the beer in your keg.

Find an equilibrium pressure from beer temperature and target carbonation. Or work backwards to find carbonation or temperature.

See the method & supported ranges

Your beer

Measurement units
°C

Measure the beer itself, not the fridge air. Supported: 0–30 °C.

vol. CO₂

Target total dissolved CO₂, not an amount to add. Supported: 1.0–4.0 volumes.

Local atmospheric pressure
hPa abs.

Default: standard sea level. For altitude correction use actual station pressure, not a weather report corrected to sea level. Supported: 500–1100 hPa absolute.

Atmosphere: standard sea level.

100% CO₂ · Equilibrium estimate · No carbonation time prediction

Your result

Equilibrium gauge pressure

Enter your beer details

— bar

An equilibrium estimate for your inputs.

The pressure, explained

Sea-level gauge equivalent
—
Atmospheric correction
—
Local gauge pressure
—
Absolute pressure
—

Absolute pressure includes the atmosphere. A regulator displays gauge pressure.

Equilibrium takes time.

This result describes the final balance at a steady beer temperature under CO₂. It does not tell you how long carbonation takes, how much gas to inject, or what temporary “burst” pressure to use.

Check the pressure rating of your keg, regulator and fittings before applying a setting. The calculator cannot verify your hardware.

Behind the calculation

Temperature. Pressure.
Dissolved CO₂.

Keep the assumptions in view before turning the regulator.

The equilibrium model

P₀ = −16.6999 − 0.0101059T
+ 0.00116512T² + 0.173354TV
+ 4.24267V − 0.0684226V²

P₀
Sea-level gauge pressure in psi
T
Beer temperature in °F
V
Total carbonation in volumes CO₂

How much confidence should I place in the result?

This empirical polynomial is documented by brewing equipment supplier GW Kent. We checked all 110 entries in Brewers Association table B.1: 33–42 °F and 2.1–3.1 volumes. The fit approximates that table; it does not reproduce every entry exactly. See the measured maximum difference below.

Reference comparison is documented in the review report.

Outside that reference rectangle, the result is explicitly marked as extrapolation from our checks. This tool is restricted to 0–30 °C and 1.0–4.0 volumes; these are implementation limits, not a claimed validated or safe operating range.

Gauge pressure, absolute pressure and altitude

The atmospheric correction is P_local = P₀ + P_standard − P_atmosphere, with all pressures in the same units and standard atmosphere = 1.01325 bar absolute. Lower local atmospheric pressure increases the gauge pressure needed for the same absolute pressure.

The optional atmospheric input accepts 500–1100 hPa absolute (about 7.25–15.95 psia). This is a tool scope limit. A higher-pressure result above 2 bar gauge is flagged for review; 2 bar is an editorial prompt, not an equipment rating.

Volumes of CO₂ and the beer behind the chart

A volume compares dissolved CO₂ gas at a reference condition with the beer volume. The traditional chart uses 0 °C and 760 mmHg for the gas. The BA reference assumes SG 1.015 and about 4.8% ABV. Different beer composition can change solubility. This version makes no ABV, sugar or gravity correction.

Use the brewer’s target carbonation where available. The value in the example is a demonstration, not a universal beer-style recommendation.

What happens at the boundaries?

Missing, nonfinite or out-of-scope inputs clear the old result and show field errors. Zero gauge pressure is allowed under pure CO₂; it does not mean exposure to air. A negative calculated gauge pressure is shown as a vacuum requirement, not a regulator setting.

Inverse calculations are restricted to the supported temperature or carbonation interval. If no solution exists there, the tool shows the compatible pressure interval instead of extending the model silently. Within these intervals, pressure increases with either temperature or carbonation, so each inverse solution is unique.

Sources & review

GW Kent · Formulas and assumptions
Published polynomial and pressure convention. We do not use its ABV correction.

Brewers Association · Draught Beer Quality Manual, 4th edition
Appendix B, printed p. 89: independent reference pressures and beer assumptions.

Zahm & Nagel · CO₂ solubility chart
Traditional volume reference conditions.

Reviewed 17 November 2026 · Version 1.0
Software and reference checks; no physical keg calibration.

From carbonation to the first pour

Measure the liquid

Use the stable beer temperature. A fridge setpoint is only a starting assumption.

Keep the gas assumption

This model uses pure CO₂. A nitrogen blend needs a separate partial-pressure calculation.

Then balance the line

Once the holding pressure is chosen, use the tubing and height to plan a starting line length.

Open Draft Line Balancing Calculator