Franklinbrew

Equipment & reference

Cleaning, Sanitation and Iodophor

Remove the soil, apply the right treatment, then verify return to service.

Separate cleaning from sanitising and use iodophor as a labelled product, with a practical record for the beer path.

Reviewed 17 November 2026 · Version 1.0

A sanitiser cannot make a dirty surface reliably clean. The useful starting point is a complete path through the equipment: what touches the beer, how it can be accessed, and how each treatment is removed or drained before service.

Give each operation a clear job

Cleaning
Remove residues and deposits using an appropriate cleaner and mechanical or flow action.
Rinsing
Remove the cleaner or other treatment when its directions require it, including verification before return to service.
Sanitising
Apply a suitable sanitiser to a prepared surface under its labelled conditions.

Sanitising is not sterilisation. A bright surface is not proof of the required treatment, and a coloured sanitiser solution is not a cleanliness test. Keep both inspection and process records.

Do not mix chemicals. Select materials, protective equipment and handling arrangements from the actual label and safety data sheet before starting work.

Map every beer-contact component

List the keg or container, pickup, disconnect or coupler, tubing, shank, faucet and any additional wetted part. Identify the approved disassembly and cleaning method for each. Isolate gas and depressurise as specified before opening or servicing equipment.

Prepare the correct cleaner, carry out its instructed process and rinse as directed. Inspect accessible surfaces. Apply sanitiser where required by the brewing or service process, then drain, air-dry or rinse only as that product directs.

A no-rinse product earns that description under specific use conditions. It does not make excessive concentration acceptable, and it does not turn an unknown chemical into a no-rinse sanitiser.

Section references: Five Star Chemicals — Star San product directions · National Chemicals — BTF Iodophor Sanitizer.

Iodophor is a product family, not one universal dose

Iodophor sanitisers use iodine in a formulated product. Use a product labelled for the intended food or brewing application; a medical iodine preparation is not automatically an equivalent substitute.

A labelled example, not a mixing recipe for all products

The National Chemicals BTF product page lists a sanitising use at 12.5 ppm with at least one minute contact, followed by air drying without rinsing. It lists a different concentration and time for disinfectant use. These conditions belong to that product and use; check your own current container label.

Measure the actual water volume and product amount. Where the method calls for concentration testing, use an appropriate iodine test method in its specified range. Do not infer an adequate concentration solely from a brown colour or assume that an old diluted solution still meets its use conditions.

Record preparation time and follow the label for solution life and replacement. Check material compatibility and staining risk with the equipment supplier. More concentrated is not a substitute for clean surfaces or correct contact time.

Section references: National Chemicals — BTF Iodophor Sanitizer.

Schedule the whole dispensing path

The Brewers Association recommends draught-line cleaning at least every 14 days. Its full method also addresses components and periodic maintenance; the interval is not a stand-alone recipe. Cask Marque’s cellar guidance specifies at least weekly line cleaning for cask service.

Choose the relevant programme for your system and clean earlier where conditions require it. A keg taking longer to empty does not postpone the cleaning requirement. Use the approved method for the tubing, fittings and faucet, including any required disassembly.

Line capacity tells you how much liquid occupies the tubing. It does not determine cleaning concentration, circulation volume, contact time or chemical dose. Our line-volume tool must not be used as a chemical-dosing calculator.

Section references: Brewers Association — Draught Beer Quality for Retailers · Cask Marque — Cellar Card.

Do not serve while chemical removal is uncertain

Complete the product’s rinse, draining and return-to-service checks. Use its prescribed verification method rather than tasting an uncertain rinse. Keep the beer path out of service if those checks cannot be completed.

Record each treatment

  • Date, system and components treated.
  • Product name and label version or batch details where available.
  • Measured water volume, product amount and concentration check.
  • Temperature, contact time and cleaning method.
  • Rinse or drain requirements, verification and person completing the work.
  • Defects, replacements and next due date.

A completed record documents what was done. It cannot replace a missing product instruction or establish that a concealed dirty component was reached by the process.

Sources & scope

References and review

Manufacturer directions were checked for the named example. No dose is presented as valid for every iodophor or sanitiser, and no chemical testing has been carried out. Historical iodophor and sanitation URLs are context for this new guide, not proof of rights to old text.

  1. Five Star Chemicals — Star San product directions
  2. National Chemicals — BTF Iodophor Sanitizer
  3. Brewers Association — Draught Beer Quality for Retailers
  4. Cask Marque — Cellar Card

Franklinbrew · Independently written reference · Version 1.0 · Reviewed 17 November 2026.