Balancing starts with the pressure the beer needs. It then asks how elevation and the dispensing path use that pressure. Cutting hose before establishing the beer condition reverses the useful order.
Set the beer condition before the hose length
Record measured liquid temperature and the beer’s target carbonation. Use the carbonation calculator to estimate a matching equilibrium gauge pressure. If the brewer specifies dispensing conditions, establish what system and gas those conditions assume.
Keep the whole beer path cold. A line-length calculation has no way to correct gas breaking out in a warm tower. If actual carbonation or tubing identity is unknown, keep that uncertainty in the record rather than turning an assumed input into a precise recommendation.
Subtract elevation and other known losses
- P
- Serving pressure, in psi gauge.
- H and k
- Faucet height above the beer level in feet; k = 0.5 psi/ft is the trade convention used in this nominal model.
- O
- Other specified pressure losses in psi at the intended flow condition.
- R and L
- Specified nominal line resistance in psi/ft; calculated length in feet.
The elevation convention is not a precise density-based hydrostatic calculation. A faucet below the beer level has negative H and adds driving pressure. The tool does not automatically subtract an unexplained extra 1 psi for a faucet.
Section references: Brewers Association — Draught Beer Quality Manual, pp. 38–39 · Micro Matic — What is restriction?.
A transparent starting estimate
Suppose P = 12 psi, H = 2 ft, O = 0 psi, and the chosen tubing data specify R = 3 psi/ft. Elevation uses 1 psi, leaving 11 psi for the line. L = 11 / 3 = 3.67 ft / 1.12 m.
This is an arithmetic example using stated nominal resistance. It does not establish that every 3/16-inch tube should be cut to 3.67 ft. Use product data for your tubing and a consistent flow condition for all resistance terms.
Do not mix psi/ft with metres. The calculator converts the units; handwritten work must do the same. Gauge pressure is pressure relative to the surrounding atmosphere, not cylinder pressure.
A negative budget is a design finding
If P − kH − O is zero or negative, there is no positive line-length solution in this model. Do not install zero hose or accept a negative length. Check height, units, losses and whether this system layout belongs within a simple direct-draw model.
A positive result must also reach the faucet. The tool checks a vertical-reach constraint, but it does not know your horizontal route, bends, service loop or cabinet clearance. A 0.4 m result is unusable for a measured 1.5 m route even if the arithmetic is correct.
Very short or long lengths and a nearly exhausted pressure budget deserve review. Our tool’s review thresholds are editorial prompts, not manufacturer ratings or experimentally validated operating limits.
Use observations to refine the estimate
Install a practical starting route with room for adjustment, without kinks. Establish stable beer temperature, check the actual setpoint and use the same clean glass and pour method for comparisons. Record volume and time if you want a reproducible flow observation; this article does not impose a universal pour-time target.
If the pour is too fast or slow, review the line data and route before trimming. Remove length cautiously: a cut cannot be undone. Keep the equilibrium pressure requirement in view instead of repeatedly lowering the regulator to disguise a dispensing problem.
If foam persists, distinguish first-after-idle foam from every-pour foam and inspect the cold path, connections and beer condition. Use the troubleshooter rather than treating every foamy pour as a resistance problem.
Section references: Micro Matic — What is restriction?.
Sources & scope
References and review
The nominal resistance equation and worked example match our existing calculator. Manufacturer resistance data and physical test pours remain necessary. A mathematical solution does not certify a usable installation.
Franklinbrew · Independently written reference · Version 1.0 · Reviewed 17 November 2026.