A useful result needs a clear meaning. Our tools distinguish an exact geometric calculation, an empirical estimate and a rule-based planning report. They do not all provide the same kind of evidence.
Draft Line Balancing: a nominal resistance budget
The model is L = (P − 0.5H − O) / R, with psi, feet and psi/ft in the reference formulation. H is faucet height above beer level, O is other specified loss, and R is nominal tubing resistance. Internal calculations retain full precision before display conversion.
For 12 psi, 2 ft rise, no additional losses and 3 psi/ft, the starting result is 3.67 ft / 1.12 m. This does not predict a guaranteed flow or give modern barrier tubing a resistance based on its ID.
Nonpositive remaining pressure produces no positive solution. Route feasibility is a further check. Thresholds such as unusually long or short lines are editorial review prompts, not product ratings.
Section references: Brewers Association — Draught Beer Quality Manual · Micro Matic — What is restriction?.
Carbonation Pressure: an empirical equilibrium model
The sea-level polynomial uses temperature T in °F and carbonation V in volumes:
Local gauge pressure adds standard atmospheric pressure and subtracts the supplied local atmosphere. Temperature and carbonation inverse modes use a bounded numerical solution inside the supported rectangle, rather than selecting an unconstrained quadratic root.
Implementation scope is 0–30°C, 1–4 volumes and 0.5–1.1 bar absolute atmosphere. The independent comparison contains 110 BA table points from 33–42°F and 2.1–3.1 volumes. Maximum observed difference is 0.36865 psi. Outside that checked rectangle, supported results are labelled extrapolation.
The tool calculates neither time nor mixed-gas composition. No inverse solution, vacuum requirement and invalid inputs are separate outcomes.
Section references: Brewers Association — Draught Beer Quality Manual · GW Kent — Carbonation equation.
Beer Line Volume: cylinder geometry
For a uniform circular bore, V = π × ID² × L / 4. With ID in mm and length in metres, this expression returns mL. Actual internal diameter is required; OD is not a substitute.
A 4 mm ID and 2 m length gives 25.13274 mL. Doubling ID multiplies volume by four. Zero length is allowed and gives zero capacity; zero diameter is rejected because it does not describe an open tube.
The US fluid ounce uses 29.5735295625 mL. It is not an Imperial fluid ounce. Fittings, cavities, foam, waste and cleaning dose are not included.
Reports preserve unknowns instead of manufacturing precision
The Kegerator Setup Wizard produces component roles and verification gaps for 1–4 connected kegs with dedicated faucets under pure CO₂. Connection families and independent pressure groups are explicit. A complete answer record is still a plan, not commissioning approval.
The Foamy Beer Troubleshooter routes observations to possible causes and useful next checks. Partial interviews and unknown answers remain visible. A symptom is not a diagnostic certainty, and no confidence percentage is manufactured from a rule count.
Both tools separate unsupported service types and conditions that should stop further testing. They do not identify fittings from a photograph, locate hidden cabinet lines or confirm chemical removal.
An invalid input must not leave a valid-looking old answer
Calculator errors appear at the relevant fields and in a summary. Missing text is not treated as zero. Nonfinite inputs, numerical overflow, incompatible bounds and no-solution states clear the former result.
Metric/US switches preserve underlying physical quantities rather than repeatedly converting rounded display text. Very small positive values must not be displayed as exact zero. Review prompts remain separate from mathematical failure and equipment limits.
Current model suites contain 16 balancing checks, 16 carbonation checks, 15 volume checks, 28 foam checks and 22 setup checks. These include boundary and routing cases; a passing count does not measure real-world diagnostic accuracy. Source comparisons and browser checks are described on each tool’s method section.
Sources & scope
References and review
Equations, unit constants, examples and stated boundaries were reconciled with the local model implementations and existing review notes. Verification is mathematical and software-based; no physical calibration is claimed.
- Brewers Association — Draught Beer Quality Manual
- Micro Matic — What is restriction?
- GW Kent — Carbonation equation
Franklinbrew · Independently written reference · Version 1.0 · Reviewed 17 November 2026.